{"product_id":"milwaukee-mw802-pro-3-in-1-ph-ec-tds-combo-meter-with-atc","title":"Milwaukee MW802 PRO 3-in-1 pH, EC, TDS Combo Meter with ATC","description":"\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eMilwaukee MW802 PRO 3-in-1 pH, EC, TDS Combo Meter – Precision \u0026amp; Convenience in Water Analysis\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eThe Milwaukee MW802 PRO 3-in-1 Combo Meter is the ultimate solution for measuring pH, Electrical Conductivity (EC), and Total Dissolved Solids (TDS) with a single, highly efficient device. Engineered with precision and designed for maximum convenience, this portable meter is an essential tool for professionals across various industries. Whether you’re managing the delicate balance of hydroponic systems, aquaculture, or food production, the MW802 PRO provides fast, reliable results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eIts advanced features, such as Automatic Temperature Compensation (ATC), ensure accurate measurements in any environment, whether in the lab, field, or production site. Hydroponic growers and aquaponics enthusiasts rely on it for real-time monitoring of nutrient solutions, helping them achieve optimal plant health and yields. Greenhouses and agricultural sectors use it to fine-tune soil and water conditions, promoting healthy crop growth while maintaining cost-effective resources.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eIn aquaculture, the MW802 PRO plays a crucial role in monitoring water quality for aquatic life, ensuring ideal conditions for fish farms or aquarium setups. With its versatility, it also serves environmental scientists and water treatment specialists in analyzing water quality in natural bodies or treatment plants.In food production, manufacturers can use it to monitor processes requiring precise water conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eFrom research laboratories to industrial water treatment facilities, the MW802 PRO is a trusted ally in measuring pH, EC, and TDS levels, providing confidence in the integrity of the water and solutions critical to each industry. The MW802is a must-have tool for professionals who demand precision and efficiency in their water analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eWhy Choose the Milwaukee MW802 PRO?\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003e\u003cb\u003e3-in-1 Functionality:\u003c\/b\u003e Measures pH, EC, and TDS with one meter and a single probe.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003e\u003cb\u003eAutomatic Temperature Compensation (ATC):\u003c\/b\u003eEnsures accuracy in all environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003e\u003cb\u003eSimple Calibration: \u003c\/b\u003eSingle-point manual calibration for both pH and EC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003e\u003cb\u003eRugged \u0026amp; Reliable:\u003c\/b\u003e Durable design with are place able SE600 probe for long-term use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003e\u003cb\u003eLight weight \u0026amp; Portable:\u003c\/b\u003e Weighs just 5.8 ounces and fits comfortably in hand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eL\u003cb\u003earge, High-Contrast Display: \u003c\/b\u003eView measurements quickly with an easy-to-read digital screen.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eHowto Use the MW802 PRO\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e\u003cb\u003eCalibrate with standard buffer solutions\u003c\/b\u003e\u003cbr\u003eCalibration is a crucial step in ensuring that the MW802 provides accurate readings. To begin, you’ll need to use standard calibration solutions with known pH, EC, and TDS values. These solutions will help set the meter to give precise readings for your specific measurements. Calibration should be performed regularly, especially if the meter is used frequently or exposed to harsh conditions. It's a good practice to calibrate before each testing session to guarantee the most accurate results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e\u003cb\u003eSubmerge the probe in the water or nutrient solution\u003c\/b\u003e\u003cbr\u003eAfter calibration, place the meter’s probe into the sample you intend to test,whether it’s water, nutrient solution, or soil mixture. Make sure the probe is fully submerged in the sample for consistent measurements. For nutrient solutions or water, ensure that the probe is immersed deep enough to measure the entire solution, allowing for accurate EC, pH, and TDS readings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e\u003cb\u003eGently stir for an accurate reading\u003c\/b\u003e\u003cbr\u003eGently stir the probe within the sample to ensure the meter gets an even,stable reading. Stirring helps to distribute any inconsistencies in the solution, such as localized differences in pH or nutrient concentration,ensuring that the reading you get is representative of the entire sample.Stirring should be done slowly and carefully to avoid damaging the probe or disrupting the sample too much.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e\u003cb\u003eAdjust pH and nutrient levels as needed\u003c\/b\u003e\u003cbr\u003eBased on the readings provided by the MW802, you may need to adjust the pH, EC,or TDS levels of your solution. If, for example, the pH is too high or too low,you can add pH up or pH down solutions to bring it into the desired range. For EC or TDS adjustments, add the appropriate nutrient solution to ensure that plants receive the necessary levels of minerals and nutrients.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e\u003cb\u003eClean and store the probe properly for longevity\u003c\/b\u003e\u003cbr\u003eAfter each use, clean the probe thoroughly to avoid the buildup of dirt, salts,or other contaminants. Proper cleaning ensures that the probe remains accurate and prevents it from becoming clogged, which could affect its readings. Once cleaned, store the probe in an appropriate solution (such as a buffer or storage solution) to keep it hydrated and prevent any damage. Avoid storing it in just water, as this can lead to contamination and shorten the lifespan of the probe.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eProper Meter Care \u0026amp; Maintenance\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eEssential Tips for Long-Lasting Performance:\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e\u003cb\u003e•Store the probe properly in buffer or storage solution (MA9015, not water)\u003c\/b\u003e\u003cbr\u003eStoring the probe in a buffer or storage solution ensures it remains moist and calibrated, extending the lifespan of the probe. Never store it in pure water,as it can cause the probe to dry out, leading to inaccurate readings and damage over time. Buffer solutions are designed to maintain the probe’s calibration and functionality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e\u003cb\u003e•Clean regularly by soaking in pH and EC cleaning solution (MA9016)\u003c\/b\u003e\u003cbr\u003eOver time, the probe can accumulate deposits from samples such as salts, oils, or other contaminants. To keep the probe in optimal condition, regularly clean it by soaking in a cleaning solution specifically designed for pH and EC probes,such as the MA9016. This ensures that any buildup is effectively removed,helping maintain the meter’s performance and accuracy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e\u003cb\u003e•Calibrate after cleaning and before testing to maintain accuracy\u003c\/b\u003e\u003cbr\u003eAfter cleaning the probe, always recalibrate the MW802 before using it for measurements. Cleaning can alter the probe’s accuracy, and calibration ensures thatit provides reliable readings. Calibration should be done with fresh standard buffer solutions to restore the meter to its optimal performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e\u003cb\u003e•Gently stir the probe in the sample for the most reliable results\u003c\/b\u003e\u003cbr\u003eWhen measuring, it’s essential to stir the probe gently in the sample to obtain the most accurate and consistent readings. Stirring helps to evenly distribute any variations within the solution, ensuring that the measurement reflects the overall conditions. Avoid vigorous shaking, which could disrupt the measurement processor damage the probe.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eBy following these detailed instructions for use and maintenance, you’ll ensure that your MW802 PRO remains accurate, reliable, and in excellent condition,giving you the best results for your water or nutrient solution analysis overtime.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eOrder the Milwaukee MW802 PRO Today!\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eWhether you're managing a hydroponic system, ensuring optimal water quality in aquariums, or monitoring nutrient levels in agriculture, the Milwaukee MW802PRO 3-in-1 Combo Meter is the versatile tool you can rely on for precise pH,EC, and TDS measurements. With its easy-to-use design and accurate results, theMW802 is perfect for professionals and enthusiasts alike, helping you maintain ideal conditions for plant growth, aquatic life, and more.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003epH Range: 0.00 to 14.00 pH\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eEC Range: 0.00 to 6.00 mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eTDS Range: 0 to 4000 ppm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003epH Resolution: 0.1 pH\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eEC Resolution: 0.01 mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eTDS Resolution: 10 ppm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003epH Accuracy: ±0.20\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eEC\/TDS Accuracy: ±2% Full Scale\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eCalibration Solutions: M10007 (pH7.01) M10032 (1382 ppm) M10442B 1500 ppm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eConversion Factor: 0.68\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eCalibration: Manual at 1 point\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eTemperature Compensation:Automatic from 0 to 50°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eProbe: SE600 combination pH\/EC\/TDS probe\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eEnvironment: 0 to 50°C \/ 32 to122°F; max RH 95%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eBattery Type \/ Battery Life: 1 x9V alkaline \/ 150 hours of use\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eAuto-off: After 8 minutes of non-use\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eDimensions: 7.3 x 3.2 x 1.8inches\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eWeight: 5.8 ounces (with battery)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Ti88TOWOwl0?si=WbjZuCDMPCEu4XIY\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":52469989769518,"sku":null,"price":1590.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/2348\/3470\/files\/mw802-1.png?v=1786952561","url":"https:\/\/www.myaquariumshops.com.my\/products\/milwaukee-mw802-pro-3-in-1-ph-ec-tds-combo-meter-with-atc","provider":"MyAquariumshops","version":"1.0","type":"link"}