{"product_id":"milwaukee-mw605-max-waterproof-galvanic-dissolved-oxygen-meter-with-auto-calibration","title":"milwaukee MW605 max waterproof galvanic dissolved oxygen meter with auto calibration","description":"\u003cp\u003emilwaukee MW605 max waterproof galvanic dissolved oxygen meter with auto calibration\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eThe Milwaukee MW605 MAX Galvanic Portable Waterproof Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eThe Milwaukee MW605 MAX DO Meter is preferred by people looking for lab level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, water treatement plants and labs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eDESIGNF EATURES\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eFast,easy-to-read results with large digital LCD readout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eGalvanic probe means no conditioning time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eRepeatable,accuracy to ±1.5% of reading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eWater Proof IP 67 Rated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eLight weight and portable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eSimple1 or 2 % saturation calibration points at 100% (water saturated air) and 0% (zero oxygen solution).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eDedicated GLP key to store and recall data on system status.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eAvailable log space for up to 1000 records.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eLogged data export via USB cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eAltitude and Salinity compensation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eAutomatic temperature compensation °F \u0026amp; °C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eUsesMA860 (included) reinforced Galvanic probe with an oxygen-permeable polytetra fluroethylene (PTFE) membrane sensor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003e2O-rings, membranes and one protective cap included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003e10feet probe cable for extra flexibility when testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003e3x 1.5 volt akaline AA battery (battery included) aprox. 200 hours of battery life with continuous use with low battery warning.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eCARE AND MAINTENANCE\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003ePROBE MAINTENANCE:\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eTHE SILVER CATHODE SHOULD ALWAYS BE BRIGHT AND UNTARNISHED. IF IT IS TARNISHED OR STAINED, THE CATHODE SHOULD BE CLEANED GENTLY WITH A LINT-FREE CLOTH.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eRinse the probe with deionized or distilled water.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eReplace the membrane cap using fresh electrolyte.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eRecalibrate meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eMembrane Maintenance:\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eFor accurate and stable measurements, perfect condition of the membrane surface is needed. Protect the thin membrane from scratches, abrasion or contact with solids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eIf no measurements are taken for a few hours, protect the membrane with the plastic protective cap.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e·       \u003c\/span\u003e\u003cspan\u003eIf fouled, rinse it carefully with distilled or deionized water. If damaged,replace the membrane cap.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eNote:Change the membrane every 8 weeks or more frequently if used in a specially fouling environment. Check and replace the electrolyte fill solution every 4weeks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eStorage:\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eAfter taking measurements, switch the meter off and clean the probe before storage.When not in use the probe should be stored with the plastic cap on.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eFor short term storage, the probe can also be stored in a beaker of deionized water with the protective plastic cap removed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003eFor long term storage, the probe should be stored dry:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e1.Disconnect the probe from the meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e2.Unscrew the membrane cap.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e3.Remove any electrolyte solution from the cap.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e4.Rinse the probe anode\/cathode assembly with distilled water and blot dry.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e5.Screw the membrane cap onto the probe until the membrane cap is hand tight.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cb\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eO2 Range*: 0.0 to 45.00 mg\/L(ppm)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eO2 Range: 0.0 to 300.0 %Saturation\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eRange Temperature**: -20.0 to120.0 °C (-4.0 to 248.0 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eO2Resolution: 0.01 mg\/L (ppm) \/0.1 % Saturation\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eTemperature Resolution: 0.1 °C(0.1 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eO2 Accuracy: ±1.5% of reading ± 1digit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eTemperature Accuracy: ± 0.4°C(±0.8°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eCalibration: One or Two %saturation calibration points 0 % (MA9070) and 100 % (water saturated air)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eTemperature Compensation:Automatic, from 0.0 to 50.0°C (32.0 to 122.0 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eAltitude compensation: -500 to4,000 m (-1,640' to 13,123') with 100 m (328') resolution\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eSalinity Compensation: Manual,from 0 to 40 g\/L ( with 1 g\/L resolution)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eLogging\/Memory: Max. 1,000 log records (stored in up to 100 lots) \/ On Demand, 200 logs \/ On Stability, 200logs \/ Interval logging, 1,000 logs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003ePC Connectivity: 1 micro USB port\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eBattery Type: 3 x 1.5V alkaline AA (included)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eBattery Life: Approx. 200 hours of use\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eDimensions Meter: 8 x 3.3 x 2.0inches (200 x 85 x 50 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eDimensions Packaging: 14 x 12 x 6.0 inches (355.6 x 304.8 x 152.4 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eWeight Meter: 0.57 lbs (260 g)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eWeight Packaged: 5.0 lbs (2.27kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eProbe MA860:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eGalvanic Probe included\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eTemperature Range: 0.0 to 50.0°C \/ 32.0 to 122.0°F\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eTemperature Sensor: Built in Thermistor\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eCathode: Silver\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eAnode: Zinc\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eMembranes: Oxygen permeable PTFE(2) included\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eConnector Socket: DIN 7pins\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eBody: PP, ABS, IP67 rating\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eCable: Jacket material: PP\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003eDo measurement is performed within automatic temperature compensation interval.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e\u003cspan\u003e§  \u003c\/span\u003e\u003cspan\u003e** Limits will be reduced to actual sensor limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNoSpacing\"\u003e \u003c\/p\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":52469984985390,"sku":null,"price":4250.0,"currency_code":"MYR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0556\/2348\/3470\/files\/mw605-3.png?v=1786952187","url":"https:\/\/www.myaquariumshops.com.my\/products\/milwaukee-mw605-max-waterproof-galvanic-dissolved-oxygen-meter-with-auto-calibration","provider":"MyAquariumshops","version":"1.0","type":"link"}